      Derating of rated voltage to operting temperature : Use of a capacitor at high temperature    shortens the capacitor life due to thermal deterioration.when operation capacitors high temperature , please derate the operating voltage in conformance    with the Fig1.
 
 | 
  
    |  | 
  
    | 
      Derating of rated voltage for high frequency : Use of a capacitor at high frequency may cause the capacitor deterioration and damage due to self-heating.
 (The allowable    value depends on dielectric. For details consult our office or sales    representative).
 
 | 
  
    |  | 
  
    | 
      Operating temperature range  : Operating temperature range  is specified as a sum of ambient    temperature, inherent temperature rise and  temperature rise by radiant heat from    other heat sources, the capacitor surface temperature is not exceeding the operating temperature range.
 
 | 
  
    |  | 
  
    | 
      Inherent temperature rise   : When capacitors are    operated in AC circuit or high frequency / high ripple current circuit ,    temperature of capacitors rises inherently,in case temperature rises too    high,performance of capacitors may be deteriorated or damaged. The inherent temperature    rise at no air circulation (Ambient temperature at 40℃) shall be within avalue specified below. (See the Table 2)
 
 | 
  
    |  | 
  
    |  | 
  
    | 
      Permissible current    : When capacitors are operated in AC    circuit / high frequency / high ripple current circuit permissible current to;  capacitor shall be less than a value Ip-p,    in case of operation at a higher current than  permissible value, performance of    capacitor may be deteriorated or  damaged because of inherent temperature    rise.
 ( as specified details consult our office or sales    representative )
 
 | 
  
    |  | 
  
    | 
      Use for Across-the-Line as Noise Suppressor : a) For    across-the-line capacitors as noise suppressor, very strict safety    performance are required in the U.S.A,CANADA and EUROPEAN countries , for this    application , choose the most suitable type   shall be selected from MPX(275Vac) series.
 b) For capacitors used as noise suppressor    in OA appliances and VA equipment like TVs and VTRs,voltage is ,in general, applied continuously for 24 hours,and moreover abnormal surge voltage ( thunder    surge ) may  be also applied unexpectedly.Such   factors give very cruel influences to   the capacitor life
 c) Safety regulations on capacitors are  classified by IEC, depending upon the usage of circuitry.
 d) Class X capacitors are suitable for applications where there is no  danger of electrical shock in case of breakdown . Class X capacitors are divided into three subclasses (See the Table 3) according to the    peak voltages of the pulses to which they are    exposed during operation in addition to the line voltage. Such impulses can be caused by lightning in    overhead lines,switching operations in neighbouring equipment or  in the equipment which is shielded by   the capacitor.
 
 | 
  
    |  | 
  
    |  | 
  
    |  | 
  
    |  | 
  
  
    
  
  