|
|
|
|
PRODUCTS |
|
|
|
|
|
|
|
|
|
|
|
Counters |
|
|
|
Rate Meter ( Model DC - 9045 RM)
|
|
Width Counter (Model DC - 9045WC) |
 |
|
 |
|
|
|
|
Technical Specifications |
|
|
|
Time Totalizer ( Model DC -9045 RM) |
Width Counter ( Model DC -9045WC) |
Panel cutout 90 x 45 mm |
Panel cutout 90 x 45 mm |
Six (6) digit display, 8mm LED |
Six (6) digit display, 8mm LED |
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA
|
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA |
Input Type |
Reset, (remote optional) |
Non Contact - Open Collector |
Input |
Range - liter / meter (per) |
Open Collector - 6000 CPS |
Hours - Minute - Seconds |
|
|
|
|
|
|
Preset Time Totalizer ( Model DC - 9090PRIT)
|
|
Preset Timer ( Model DC -9090PRT) |
 |
|
 |
|
|
|
|
Technical Specifications |
|
|
|
Preset Time Totalizer ( Model DC -9090 PRIT) |
Preset Timer ( Model DC -9090PRT) |
Panel cutout 90 x 90 mm |
Panel cutout 90 x 45 mm |
Six (6) digit display, 8mm LED |
Six (6) digit display, 8mm LED |
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA
|
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA |
Preset in SET mode for each digit |
Preset in SET mode for each digit up to 4 level |
Range - Multi Range |
Range - Multi Range |
Hours - Minutes - Seconds |
Hours - Minutes - Seconds |
Output -2 Pairs of Potential free contacts |
Output up to 8 pairs of potential free |
Memory - Last count 72 Hours |
Memory - Last count 72 Hours |
|
|
|
|
Preset Counter( Model DC - 9090PRC)
|
|
Preset RPM Counter( Model DC - 9090PRRPMC) |
 |
|
 |
|
|
|
|
Technical Specifications |
|
|
|
Preset Counter ( Model DC -9090PRC ) |
Preset RPM Counter ( Model DC -9090PRRPMC ) |
Panel cutout 90 x 90 mm |
Panel cutout 90 x 90 mm |
Six (6) digit display, 8mm LED |
Six (6) digit display, 8mm LED |
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA
|
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA |
Reset, (remote optional) |
Preset in SET mode for each digit |
Preset in SET mode for each digit up to 4 level |
Input - Non contact,open Collector |
Direction - Auto / Manual |
Output -2 pairs of potential free contacts |
Input - Open Collector -600 cps |
(230V/6A, 50 Hz, open collector) |
Output - up to 8 pair of potential free contact |
Memory - Last count 72 Hours |
Memory - Last count 72 Hours |
|
|
|
|
|
Block Rotor Protector ( Model DC - 9090BRP) |
|
Die Height Counter ( Model DC - 9090DHC) |
 |
|
 |
|
|
|
|
Block Rotor Protector ( Model DC -9090BRP ) |
Die Height Counter ( Model DC -9090DHC) |
Panel cutout 90 x 90 mm |
Panel cutout 90 x 90 mm |
Six (6) digit display, 8mm LED |
Six (6) digit display, 8mm LED |
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA
|
Supply - 110V/ 230V, 50Hz, 5VA
12 to 24 VDC, 100 mA |
Preset in SET Mode |
Preset in SET Mode for each digit for 2 levels |
Input - Non contact, open collector |
Reset, (remote Optional) |
Output 2 pairs of potential free contacts |
Input -Built -in Encoder |
(230V/6A, 50 Hz, open collector) |
Output 2 pairs of potential free contacts |
|
(230V/6A, 50 Hz, open collector) |
Memory - Last count 72 Hours |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Copyright © 2007 Madhu Subtronic Components Pvt. Ltd. All rights reserved. |